User's Manual

Installation
3A0294G 33
7. Install the pressure sensor on the pump bleed port.
a. Use a wrench to remove the pressure valve.
b. Apply the supplied sealant to the adapter (33),
the manifold (34), and the pressure valve. Install
all three in the order listed. See F
IG. 61.
c. Disconnect pressure sensor at PT1.
d. Install the o-ring (38) and pressure sensor (35);
use zip ties (32) to secure the cable to the ram
and air hose.
8. Install cables. Reference the cable identification
table on the next page and F
IG. 63 for a diagram of
cable connections.
FIG. 60: Remove Pressure Valve
FIG. 61: Install Pressure Sensor
Pressure Valve
Pressure
Valve
33
34
35
38
FIG. 62: Breakout Module Connections
Pressure
Sensor
Extension
Air Motor
Cable
Cable
LCM Cable
Solenoid
Extension
Cable
Light Tower
Shot Status
Drum Low (1)/
Start/Stop (2)
Not Used
Changeover
Solenoid