User's Manual
Installation
3A0294G 27
d. Install the o-ring (33) and pressure sensor (32);
use zip ties (35) to secure the cable to the ram
and air hose.
11. Install cables. Reference the table below and FIG.
46 for a diagram of cable connections.
FIG. 43: Install Pressure Sensor
Pressure
Valve
r_262370_3A0294_20a
32
30
31
33
FIG. 44: Breakout Module Connections
FIG. 45: Connect Linear Sensor/Reed Switch Cable
Pressure
Sensor
Extension
Air Motor
Cable
Cable
LCM Cable
Solenoid
Extension
Cable
Light Tower
Shot Status
Drum Low (1)/
Start/Stop (2)
Not Used
Changeover
Solenoid
r_262371_3A0294_75a
Connect
Cable
20
262371 Cable Identification
Description Part Labels (relative to graphic)
Length
in. (mm) Connectors
Power Cable
121226 PS1 None 16
DB25
15T859 1(blue) None 120
Pigtail
16G589 AM1 LS1/RS1 52
Motor cable
15Y051 9(grey) AM1 118
Solenoid Extension
122030 3(red) Y1(yellow)
20
Accessory Kit
5(grey) Y2(orange)
Air Solenoid
121806 AV 1(yellow)
20
Fluid Solenoid
FV 2(yellow)
Pressure Sensor Exten-
sion
16F562 6(blue) PT1 80