User's Manual
Installation
26 3A0294G
8. Install the linear sensor (17).
a. Remove the lift ring or plug.
b. Insert magnet and magnet holder into the top of
the motor shaft using the magnet installation
tool.
c. Install the linear sensor assembly into the top
plate of the air motor.
9. Install the reed switch assembly (20).
a. Remove the air line to the motor.
b. Adjust the air fitting to make room for the reed
switch (20).
c. Install the reed switch (20) into the air valve as
shown in F
IG. 41, and secure with the screw
(21).
NOTE: For air motor models M07xxx, M12xxx, and
M18xxx, which have the large mufflers, remove the muf-
fler before installing the reed switch. Reinstall the muf-
fler after the reed switch in installed.
10. Install the pressure sensor on the pump bleed port.
a. Use a wrench to remove the pressure valve.
b. Apply the supplied sealant to the adapter (30),
the manifold (31), and the pressure valve. Install
all three in the order listed. See F
IG. 43.
c. Disconnect pressure sensor at PT1.
FIG. 40: Install Linear Sensor
ti18237a
17
Magnet
Magnet
Holder
Motor
Shaft
FIG. 41: Install Reed Switch
FIG. 42: Remove Pressure Valve
r_262374_3A0294_71a
Muffler
20
21
Pressure Valve
r_262370_3A0294_19a