User's Manual
Installation
16 3A0294G
Installation
The procedures in this section are specific to each shot
dispense kit. Follow only the installation instructions for
your particular kit.
For supply system or pump assembly installation
instructions, refer to the Supply Systems Operation
manual or your pump packages instructions-parts man-
ual.
Location
NOTE: SmartWare Shot Dispense kits are not approved
for use in explosive atmospheres.
Follow the location guidelines and instructions provided
in the Supply Systems Operation manual or your pump
packages instructions-parts manual before installing the
shot dispense kit.
Install Kits 262370 and 262372
1. Close both shutoff valves on the air control panel.
2. Install the power supply bracket (33) to the ram post
using four screws (29) and lock washers (28).
FIG. 10: Close Shutoff Valves
FIG. 11: Install Power Supply Bracket
Shutoff
Valve
Shutoff
Valve
33
28
29
r_262370_3A0294_6a