Appendix A - User Interface Display
3A0294G 101
Information Screen
This screen displays the present alarm or advisory,
along with the current error icon and error code. The
information screen also displays the current volume of
material in the drum. This screen also displays the aver-
age overshoot and the largest deviation from the aver-
age overshoot.
Users can clear alarms or advisories and reset the drum
volume from this screen.
There are three alarm possibilities:
The information screen is accessed by pressing either
from the run screen.
Icon Function Description
Advisory Advisories do not require atten-
tion; therefore, the system con-
tinues running and
displays next to the operation
mode field.
Deviation Deviations require attention, but
not immediately; therefore, the
system continues running and
displays next to the oper-
ation mode field.
Alarm Alarms require immediate atten-
tion; therefore, the system dis-
ables and the Information
screen automatically displays.
Current Error Code
Alarm or Advisory
Current Drum Volume
Current Error Icon
Overshoot Icon
Average Overshoot
Largest Deviation