User's Manual

Setup
14 3A0261H
Setup
Motor Driven
1. Connect Dispense Valve I/O, Start Options, and
Motor logic cables. If level controls are installed,
connect Level Controls logic cables.
2. Adjust customer supplied air pressure regulator to
80 psi (0.6 MPa, 6 bar).
3. Perform Setup procedure for dispense valve and
feed system components. See Related Manuals on
page 3.
Adjust Amplifier
The amplifier should be adjusted if:
Debris or vibration changed the distance/axis
between the sensor and metering block (13).
Replacing the sensor.
1. Navigate to the Motor Status screen.
2. Ensure the metering rod connection block (13) is
aligned with the sensor.
3. If the display shows a “0” for the sensor switch being
adjusted, increase the amplifier intensity adjustment
screw until the sensor switch display changes to “1”.
4. Repeat for each sensor switch installed on assem-
bly.
NOTICE
Feed system and main logic control system must
use separate air supplies.
VERIFY INCOMING VOLTAGE
BEFORE CONNECTING POWER
WITH VOLTAGE SWITCH SETTING
VALVE I/O
MOTOR
3
24
1
AUDIO ALARM
START OPTIONS