User's Manual
Technical Data
3A0260H 99
Technical Data
* Flow rates and viscosities are general estimates. Flow rates drop as viscosity increases. Fluids are expected to
shear under pressure. New applications or fluids should always be tested to determine proper line sizes and
equipment selections. See your Graco Authorized distributor for other capabilities.
Volume repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . +/- 1%
Minimum Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 cc/rev model: 30 cc/min
20 cc/rev model: 40 cc/min
Maximum Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 cc/rev model: 480 cc/min
20 cc/rev model: 1600 cc/min
Minimum Dispensed Shot Size . . . . . . . . . . . . . . . . . . . 6 cc/rev model: 8 cc
20 cc/rev model: 10 cc
Maximum Fluid Working Inlet Pressure . . . . . . . . . . . . . 1500 psi (10.3 MPa, 103 bar)
Maximum Fluid Working Outlet Pressure . . . . . . . . . . . 2500 psi (17.2 MPa, 172 bar)
Air Supply Pressure Range . . . . . . . . . . . . . . . . . . . . . . 60-100 psi (filtration required)
Fluid Filtration Recommended. . . . . . . . . . . . . . . . . . . . Up to 200 mesh, depending on viscosity
Viscosity Range of Fluids . . . . . . . . . . . . . . . . . . . . . . . 1,000-1,000,000 Centipoise
Wetted Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stainless Steel, Tool Steel, Chrome, Carbide, Acetal
Plastic, PTFE, Chemical Resistant O-Rings
Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . Full Load: 18.5A, Fuse Rating: 21A
Power Supply Voltage Range . . . . . . . . . . . . . . . . . . . . 240VAC, 50-60 Hz, single phase
Sound Pressure Level at Maximum Flow Rate . . . . . . . 6 cc/rev model: 58 dB(A)
20 cc/rev model: 72 dB(A)
Sound Power Level at Maximum Flow Rate . . . . . . . . . 6 cc/rev model: 68 dB(A)
20 cc/rev model: 79 dB(A)
Operating Temperature Range . . . . . . . . . . . . . . . . . . . Control: 40-104°F (4-40°C)
Heated Pump: 40-400°F (4-204°C)
Ambient Pump: 40-120°F (4-49°C)
Operating Humidity Range . . . . . . . . . . . . . . . . . . . . . . 10-90% non-condensing
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 cc/rev model: 30 lb (13.61 kg)
20 cc/rev model: 60 lb (27.22 kg)
Controls: 100 lb (45.36 kg)
Overall Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 cc/rev model: 19.75 H x 9.38 W x 6.6 D in.
(50.17 H x 23.83 W x 16.76 D mm)
20 cc/rev model: 21.75 H x 9.5 W x 8.9 D in.
(55.25 H x 24.13 W x 22.6 D mm)
Control: 30 H x 24 W x 12D in.
(76.2 H x 60.96 W x 30.48 D mm)