User's Manual
Appendix A - User Interface Display
3A0260H 89
Setup #2 Screen
Overview
The Dispense Mode, Flow Rate, and Dispense Duration
settings apply to Automatic Control Mode (A)
only. Values changed on this screen independent of
changes made on the Maintenance screen.
The Bead Scale value is a duplicate to the Bead Scale
setting on the Home Screen, which can be enabled or
disabled from the Setup #1 screen. See Setup #1
Screen on page 88 for more information.
Fixed Command cc/min
Flow rate can be entered here. This field is only used
when command value source is set to Display on Setup
Screen 1. See Setup #1 Screen on page 88 for more
information.
#1 to #6 Buttons
Press to navigate to the Setup Screen with that number.
For example, press #3 to navigate to Setup Screen #3.
Pre-Charge
This is the pressure between the meter and the dis-
pense valve when the dispense valve is closed. If the
pre-charge setting is non-zero then, immediately after
dispensing, the gear meter will continue to rotate after
the dispense valve closes until the pre-charge pressure
value is achieved. The maximum Pre-Charge value is
2500 psi (17.2 MPa, 172 bar).
A
Larger values for the On Delay setting lead to larger
pressures in the system. If a value too large is input,
the machine could over-pressurize leading to rup-
tured components and serious injury.