User's Manual
Appendix A - User Interface Display
3A0260H 85
Home Screen
Manual Mode
In Manual Mode, the machine only accepts signals from
the User Interface touch screen and the physical buttons
on the machine. All signals from an External Control
Interface to initiate a shot will be ignored.
Automatic Mode
In Automatic Mode, the machine only accepts initiate
shot signals from an external machine. All signals to ini-
tiate a shot using the User Interface touch screen or the
physical buttons on the machine will be ignored.
Bead Scale
The bead scale function adjusts the quantity dispensed
by the scale percent value shown. For example, if the
system is setup to dispense 100 cc/min and the bead
scale setting is 110 then the machine will dispense
100 cc/min x 110% scale =110 cc/min.
The primary purpose of the bead scale is to be able to
quickly adjust volume dispensed to be able to find that
actual desired volume. Once the correct volume is
found, the flow rate should be adjusted accordingly.
Screens Navigation
Access to the Setup screens requires the Supervisor
password.
Flow Rate Display
The Home screen will display the commanded Flow
Rate from 1 of 3 sources:
• 1 - Maintenance Flow Rate (see Maintenance
Screen on page 86)
• 2 - Auto Mode Display Flow (see Setup #2 Screen
on page 89)
• 3 - Remote 0-10 VDC Command Flow (see Appen-
dix B - I/O on page 95)
Key:
N Enable Manual mode
P Enable Automatic mode
R Increase Bead Scale
S Decrease Bead Scale
T Current Bead Scale setting
U Navigate to Maintenance Screen
V Navigate to Robot I/O Screen
W Navigate to Setup Screens
X Navigate to Main Screen
Y Navigate to Alarm Screen
N
P
V
W
X
R
S
T
U
Y