User's Manual

Repair
3A0260H 49
Gear Pump Maintenance Guide
Review these guidelines prior to performing any mainte-
nance on the pumps.
Do not run pump dry.
Do not pull from a vacuum or negative suction head.
Do not flush with water or other non-lubricating fluid.
Do not pump corrosives, abrasives and/or fluids car-
rying particles that may harm the pump.
Do not heat or cool pump faster than 180°F (100°C)
per hour
Do not drop disassembled parts on a hard surfaces
and do not let parts knock together.
Never strike the pump parts with an iron hammer.
The parts are designed to drop in place if properly
aligned. Use arbor press to insert or remove press
fit components.
Do not use pliers to lift the gears.
Never use a screwdriver to pry the gears upward.
Apply clean oil or compatible fluid during assembly.