User's Manual
Errors
3A0260H 35
13 Pre-Charge Timeout Pre-Charge Pressure
was not reached
after dispense
Advisory Pre-Charge value
not set correctly
Set Pre-Charge to
zero. Monitor outlet
pressure; Adjust
Pre-Charge pressure
14 High Pressure Inter-
lock OFF
Pressure limit is
bypassed
Advisory Pressure sensors
are disabled
Contact Graco cus-
tomer service
15 Dispense Valve Open
(Auto Default)
Dispense valve is
open
Advisory Dispense valve
open button has
been selected
From the Mainte-
nance screen select
Dispense valve Auto
16 Calibration is enabled
complete calibration
procedure
Calibration mode
enabled
Advisory Calibration
enabled selected
from the calibrate
screen
Complete calibration
procedure
17 Drive Fault, Cycle
Power
Motor drive is dis-
abled
Alarm Various conditions Cycle Power verify
motor torque during
dispense
18 Calibration out of
range
Calibration values
are out of range or
flow rate is too low
for current K factor
Advisory Improper calibra-
tion, flow rate too
low, or pump wear
Perform calibration
procedure
Error
No.
Error Name Error Description
Error
Type
Cause Solution