User's Manual
Errors
34 3A0260H
4 Inlet Low Pressure
Error
Inlet material pres-
sure below min limit
Alarm Feed pressure too
low. Limits are not
set correctly.
Verify pressure limits
in Setup Screen 5.
Verify supply pres-
sures during dis-
pense.
5 Outlet Pressure Devi-
ation
Outlet material pres-
sure outside limits
Deviation Back pressure is
too high or too low.
Limits are not set
correctly
Verify pressure limits
in Setup Screen 5.
Verify outlet pressures
during dispense.
6 Outlet High Pressure
Error
Outlet material pres-
sure above max limit
Alarm Back pressure is
too high. Limits
are not set cor-
rectly
Verify pressure limits
in Setup Screen 5.
Verify outlet pressures
during dispense.
7 Outlet Low Pressure
Error
Outlet material pres-
sure below min limit
Alarm Outlet pressure
too low. Limits are
not set correctly.
Verify pressure limits
in Setup Screen 5.
Verify outlet pressures
during dispense.
8 Inlet Max Pressure
Fault - Relieve Pres-
sure and Cycle Power
Inlet material pres-
sure exceeds max
rated pressure
Alarm Feed system pres-
sure is set too
high. Pressure
sensor damaged.
Perform pressure
relief procedure.
Change inlet supply
pressure. Cycle
power; Verify Pres-
sure sensor is work-
ing properly.
9 Outlet Max Pressure
Fault - Relieve Pres-
sure and Cycle Power
Outlet material pres-
sure exceeds max
rated pressure
Alarm Dispense valve
not opening. Flow
rate too high.
Material not at
temperature
Perform pressure
relief procedure;
Cycle Power; Verify
Dispense valve func-
tion; Perform weight
check verification;
Reduce flow rate
10 Drive Torque Devia-
tion
Motor exceeds con-
tinuous rated torque
Deviation Flow rate too high.
Dispense Valve
not opening.
Material not at
temperature
Lower flow rate;
reduce outlet pres-
sure drop; Verify
material temperature
11 Drive Torque Error Motor exceeds con-
tinuous rated torque
Alarm Flow rate too high.
Dispense Valve
not opening.
Material not at
temperature
Lower flow rate;
reduce outlet pres-
sure drop; Verify
material temperature
12 Drive Peak Torque
Error - Drive disabled,
Cycle Power
Motor exceeds peek
torque rating
Alarm Flow rate too high.
Dispense Valve
not opening.
Material not at
temperature
Cycle Power Lower
flow rate; reduce out-
let pressure drop; Ver-
ify material
temperature
Error
No.
Error Name Error Description
Error
Type
Cause Solution