User's Manual

Errors
3A0260H 33
Errors
View Errors
Errors can be viewed from the Home screen or from the
Alarm View screen.
There are three levels or errors: alarms, deviations, and
advisories. Alarms are critical and require immediate
correction; therefore the system automatically shuts
down. Deviations are important and require attention but
not immediately. Advisories are not critical but still
require attention.
NOTE:
Errors set the dispenser ready signal LOW.
Advisories and deviations do not set the dispenser
ready signal LOW.
Diagnose Errors
See Error Codes and Troubleshooting for valid error
codes, possible causes, and solutions.
Clear Errors and Reset Control
Unit
From the Alarm View screen, press to clear an
error before restarting the control unit.
NOTE: See the Configure Errors section on page 22.
Error Codes and Troubleshooting
Access the Alarm
View screen
Error Message
Error
No.
Error Name Error Description
Error
Type
Cause Solution
PGM Control Errors
1 Control Power Off Control power has
been removed
Advisory Stop button or
E-stop
Press Control Power
button
2 Inlet Pressure Devia-
tion
Inlet material pres-
sure outside limits
Deviation Feed pressure set
too high or too low.
Limits are not set
correctly
Verify pressure limits
in Setup Screen 5.
Verify supply pres-
sures during dis-
pense.
3 Inlet High Pressure
Error
Inlet material pres-
sure above max limit
Alarm Feed pressure too
high. Limits are
not set correctly.
Verify pressure limits
in Setup Screen 5.
Verify supply pres-
sures during dis-
pense.