User's Manual
Installation
14 3A0260H
Install Control Center
Mount
Ensure the following criteria are met before mounting
the PGM control center:
• Select a location for the control center that allows
adequate space for installation, service, and use of
the equipment.
• For best viewing, the user interface should be
60-64 in. (152-163 cm) from the floor.
• Ensure there is sufficient clearance around the con-
trol unit to run cables to other components.
• Ensure there is easy access to an appropriate elec-
trical power source. The National Electric Code
requires 3 ft. (0.91 m) of open space in front of the
control center.
• Ensure there is easy access to the power switch.
• Ensure the mounting surface can support the weight
of the control center and the cables attached to it.
Secure the control center with appropriate size bolts
through the 0.50 in. (13 mm) diameter holes. See the
mounting dimensions in the following table and F
IG. 5.
Control Center Assembly Measurement
A
24.0 in. (610 mm)
B
22.5 in. (572 mm)
C
30.0 in. (762 mm)
D
28.5 in. (724 mm)
F
IG. 5: Control Center Dimensions
A
B
C
D