User's Manual

Optional Equipment
56 3A0238P
Hydraulic RTD Sensor Kit 24E348
Ref.
No. Part Description Qty
521 15T071 HOUSING, temp, rtd
1
522 15T072 GRIP, cord, straight through
1
523 124262 SENSOR, rtd, 1 kohm, 6 ft
1
524 121686 CABLE, m8 x m8, 4p,fxm,stxrt,
2m
1
Apply sealant to threads prior to assembly.
Remove plug (223) from (206).
Connect signal end of (523) to (524).
Route and cable tie (524) with existing signal-wire bundle
and connect free end of (524) to port #4 of FCM.
Apply a minimal amount of thermal grease to contact end
of (523).
1
2
3
4
5
524
4
3
521
1
522
523
5
r_257840_3a0238_24E348