User's Manual
Repair
30 3A0238P
Remove Motor
1. Shutdown the system. See Shutdown on page 21.
2. Remove Hydraulic Power Pack. See page 27.
3. Disconnect the tube assembly (15Y684) from the
accumulator (242).
4. Remove two hex head cap screws (258) connecting
the support bracket (257) to the hydraulic housing
(206).
5. Carefully remove motor assembly from tank.
6. Remove the four socket head cap screws (204) con-
necting the motor adapter plate (203) to the hydrau-
lic housing (206).
7. Remove four hex head cap screws (244), accumula-
tor (242), and mounting plate (240) from the motor
(201).
NOTE: Do not lose the spider coupler (213).
8. Remove four socket head cap screws (205) and
motor (201) from the motor adapter plate (003)
9. Loosen the set screw from the motor coupler (202)
and remove the motor coupler.
FIG.27
242
238, 239
201
264
240
247
258
257
206
237
FIG.28
201
205
203
202
213
204
206
212