User's Manual
Repair
28 3A0238P
5. Disconnect heat exchanger inlet hose (76) and fit-
ting from elbow fitting (249) on hydraulic housing
(206). Disconnect heat exchanger outlet hose (77)
and fitting from elbow fitting (248).
6. Remove the two bolts from (258) from the fluid
housing (206) and replace each with a 5/16-18
thread eye bolt. Install a third 5/16-18 eye-bolt as
indicated.
7. Run a rope through the three eye-bolts and between
the motor and the accumulator. Secure to a hydrau-
lic lift.
8. Remove the four bolts (57) and washers (56) secur-
ing the tank to the stand.
9. Lift the hydraulic power pack (55) and place on a
sturdy location capable of supporting up to 300 lbs
(136 kg).
FIG. 23:Heat Exchanger Inlet and Outlet Hoses
FIG.24
76
206
249
248
77
206 258
258
Install third eye-bolt here
FIG.25
To prevent serious injury from the hydraulic power
pack falling, ensure that the hydraulic power pack is
secured to the hydraulic lift before removing from the
stand.
56, 57
56, 57
55