User's Manual

Setup
20 3A0238P
Connect Electrical Cord
Electrical Requirements. See Table 1.
* Full load amps with all devices operating at maximum
capabilities. Fuse requirements at various flow rates and
mix chamber sizes may be less.
See 400 V Power Requirements, page 3.
NOTE: Power cord is not supplied. See Table 2.
See 400 V Power Requirements, page 3.
Electrical Cord Wires by Model
230V, 3 phase: L1, L2, L3
400V, 3 phase : L1, L2, L3, N
See 400 V Power Requirements, page 3.
Use 5/32 or 4 mm hex allen wrench to connect three
power leads to L1, L2, and L3.
Installing this equipment requires access to parts
which may cause electric shock or other serious
injury if work is not performed properly. Have a quali-
fied electrician connect power and ground to main
power switch terminals, see FIG. 15. Be sure your
installation complies with all National, State, and
Local safety and fire codes.
Table 1: Electrical Requirements
(kW/Full Load Amps)
Model
Voltage
(phase)
Full Load
Peak Amps*
System
Watts
230V 230V (3) 17 4000
400V 400V (3) 18 3200
Table 2: Power Cord Requirements
Model Cord Requirements AWG (mm
2
)
230V 10 (5.3), 3 wire
400V 10 (5.3), 4 wire
FIG. 15: 230V, 3 phase shown
FIG. 16: 400V, 3 phase shown
L1
L2
L3
L1
L2
L3
N