User's Manual
Setup
16 3A0238P
✖ Not used for S-Head and GX-16 applicators.
3. Hand tighten each fitting.
4. Tighten each fitting 1-1/2 flats past hand tight.
Connect Hydraulic Hoses to Applicator
If the AC power pack (A) has a boom (C), these connec-
tions will be hanging off the end of the boom.
L-Head
See FIG.8.
1. Connect the A1 hose, with green/green markings, to
the cleanout close port (CC) on the applicator.
2. Connect the A2 hose, with the green markings, to
the material close port (MC) on the applicator.
3. Connect the B1 hose, with the green/white/green
markings, to the cleanout open port (CO) on the
applicator.
4. Connect the B2 hose, with the green/white mark-
ings, to the material open (MO) port on applicator.
5. Hand tighten each fitting.
6. Bleed air from the hydraulic fluid lines. See the
applicator manual for instructions.
7. Tighten each fitting 1-1/2 flats past hand tight.
Hydraulic
Hose Fitting
Hydraulic
Hoses
Hydraulic Hose
Color Markings
A1✖ Cleanout close Green/Green
A2 Material close Green
B1✖ Cleanout open Green/White/Green
B2 Material open Green/White
FIG. 6: L-Head Applicator Hydraulic Housing
FIG. 7: S-Head Applicator Hydraulic Housing
B2
A2
A1
B1
B2
A2
ti17743a
FIG. 8: Hydraulic connections on L-Head
CC
CO
MO
MC