Repair-Parts Horizontal Hydraulic Driver 3A0020A ENG For use with two horizontally mounted proportioning pumps. For professional use only. Not for use in explosive atmospheres. 258771 - Horizontal Hydraulic Driver 1200 psi (8.2 MPa, 82.7 bar) Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual and all supplied manuals. Save all instructions.
Warnings Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3 3 4 6 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Mounting Hole Layout . . . . .
Repair Repair Disassembly 1. Relieve pressure. See system manual for pressure relief instructions. NOTICE Recommended Hydraulic Oil 2. Use two people to lift and clamp the cylinder (1) in a vise. Use Graco-approved Hydraulic Oil, Part No. 169236 (5 gal) or 207428 (1 gal)) or a premium, ISO grade 46 petroleum-based hydraulic oil containing rust and oxidation inhibitors and anti-wear agents. NOTICE To prevent damage to sealing surfaces, do not clamp any sealing surfaces in the vise.
Repair Assembly Residual hydraulic oil in the cylinder can spray out of ports during removal of the piston assembly. NOTE: Be careful not to damage piston rod assembly (9). 7. Place a cloth over the hydraulic ports (P). Use a rubber mallet to tap piston rod assembly (9) out of cylinder (1). NOTE: Be careful not to damage piston rod assembly (9). 1. Clamp piston rod (9) flats or hex in a vise to prevent damage to the piston rod. 2.
Repair 5. Lubricate inside of cylinder (1) with hydraulic oil to allow easy installation of piston assembly. Continue to next step if the cylinder hasn’t been flushed and there is residual hydraulic oil. 9. Install second seal housing (2) on cylinder (1). Torque to 150-160 ft-lbs (203-216 N•m). NOTE: Use a rubber mallet to gently tap seal housing while turning by hand to start threading the seal housing into cylinder. 1 1 2 lubricate with hydraulic oil r_258640_3A0020A_6h 6.
Parts Parts 1 1 2a 2 2 5 3 9 r_258640_3A0020A_12h 1 5 3 4 3 9c 1 1 2x 1 2a 1 2 2 4 3 9a r_258640_3A0020A_13h 9b 1 1 Lubricate seals and surfaces with hydraulic oil. 2 Torque to 150-160 ft-lbs (203-216 N•m). 3 Apply pipe sealant. Ref. 1 2 2a 4 5 9 9a 9b◆ 9c◆ Part Description Qty.
Parts 3A0020A 7
Dimensions Dimensions 17.375 in. (441.3 mm) r_258640_3A0020A_14h Mounting Hole Layout C B F A D E r_258640_3A0020A_15h G r_258640_3A0020A_17h 8 A 6.165 in. (156.6 mm) B 5.114 in. (129.9 mm) C 6.5 in. (165.1 mm) D 4.43 in. (112.5 mm) E 5.906 in. (150 mm) 120° bolt circle F 6.26 in. (159.0 mm) G 4 in. (101.
Technical Data Technical Data Maximum hydraulic working pressure . . . . . . . . . . . . . . . Maximum fluid temperature . . . . . . . . . . . . . . . . . . . . . . . Maximum hydraulic fluid flow . . . . . . . . . . . . . . . . . . . . . . Maximum cycle rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hydraulic fluid consumption . . . . . . . . . . . . . . . . . . . . . . . Effective piston area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Piston rod diameter . . . . . . . . . .
Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.