User's Manual

Installation
8 3A0006D
Schematic Diagrams
F
IG
. 4. System Schematic Diagram, Non-Hazardous Area
PRESSURE TRANSDUCER
4-20ma BARRIER
ALARM OUTPUT
(ACS RUNNING)
NON-HAZARDOUS
ACS CONTROL HANDLES:
- TDC INPUT
- 4 TO 20ma PRESSURE FEEDBACK
(0 - 500 PSI)
- CALCULATES POSITION (DEG)
- DRIVE ANALOG OUT RELATIVE TO
REQUIRED SPEED PER DEGREE
B = SLEEP MODE INPUT FROM PLC
OR FROM COMMUNICATIONS/TOUCH
SCREEN
ACS MODULE
RESET
SECURE
DISABLE
ANALOG DRIVE SIGNAL
RS485 COMS / 24VDC POWER
TO MULTIPLE ACS MODULES AND
OPTIONAL EITHERNET ROUTER/SWITCH
EXAMPLE:
ALLEN BRADLEY VFD
(22A-D8P7N104)
CONNECTION DETAILS
R/L1 T/L3
W/T3V/T2U/T1S/L2
3 PHASE AC IN
EFLO MOTOR
I/O SWITCH
MUST BE IN
SNK POSITION
02 04 05 060301
11 13 16151412
01 STOP INPUT/
SECURE DISABLE
02 RUN/FWD
03 RUN/REV
04 COM
05 DIGITAL IN 1
06 DIGITAL IN 2
11 +24VDC
12 +10VDC
13 0 - 10VDC IN
14 ANALOG COM
15 4-20ma IN
16 RS485 SHLD
TERMINALS 01 AND 04 CONNECT TO THE SECURE DISABLE
SWITCH. (LIKE AN E-STOP BUT THIS DOES NOT
DISCONNECT POWER, JUST DISABLES THE VFD.)
TERMINALS 02 IS FOR STOPPING AND STARTING THE PUMP.
02 OR 03 TO RUN THE PUMP IN A SPECIFIC DIRECTION.
THE REQUIRED MOTOR DIRCTION IS CCW WHEN LOOKING
AT FAN. TO CHANGE MOTOR DIRECTION, SWAP 3 PHASE
OUTPUT T1/T2 OR T2/T3 OR T3/T1.
ENSURE
THERMISTOR
WIRES ARE
CONNECTED
FROM MOTOR
RESET TO +
ACS MODULE -
LINE LOAD
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
13
14
15
7
8
9
13
14
15
PRESSURE TRANSDUCER
4-20ma BARRIER
(16A633)
TDC AND POSITION
SENSOR BARRIER
ALL SWITCHES "ON"
POSITION / POSITION I
(16A630)
BARRIER
WIRING DETAIL
ACS MODULE
WIRING DETAIL
EXAMPLE:
ALLEN BRADLEY VFD
WIRING DETAIL
TDC + J2 - 3 GRN
TDC - J2 - 4 BLK
POS + WHT
POS - BLK
TDC+
TDC- / POS-
POS+
24 VDC
COMMON
-
+
24 VDC
COMMON
8
9
FROM 16A630
7
8
FROM 16A630
8
7
FROM 16A633
8 CONDUCTOR CABLE
WITH SHIELD
BELDEN #9504 OR EQUIV.
ACS ANALOG VFD -
ACS ANALOG VFD +
15
14
FROM VFD
2 WIRES ON
TERMINAL 8
TO ACS SWITCH
+ J3 - 1 RED
- J3 - 2 BLK
ALARM INTERUPT OF START/STOP INPUT
TDC AND POSITION
SENSOR BARRIER