User's Manual
Technical Data
3A0006D 43
Technical Data
Dimensions
Inputs
Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-30 Vdc, 200mA, reverse polarity protected
Analog inputs: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 inputs for 4-20mA current loop sensing. Inputs pro-
tected from direct application of 24 Vdc.
Digital inputs: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 inputs: TDC, Position Sensor, AutoSleep, and Reset.
Digital inputs are 24V logic level NPN.
Outputs
4-20 mA loop:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 channels, adjustable offset and span.
Digital outputs: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 open contact, normally open relay outputs, 24V, 1A,
used for BPR control and Drive Enable.
Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Ethernet port and 1 RS485 port
Ambient Conditions
Operating temperature range. . . . . . . . . . . . . . . . . . 0-50°C (32-121°F)
Operating humidity. . . . . . . . . . . . . . . . . . . . . . . . . . 10-90% relative humidity, non-condensing
ACS
M
o
d
u
l
e
A
B
C
Module A B C Weight
ACS 2.31 in.
(59 mm)
4.49 in.
(114 mm)
5.13 in.
(130 mm)
1.1 lb
(0.50 kg)
NOTE: Designed for DIN rail mounting.
ti17553a