User's Manual

ACS Features
40 3A0006D
ACS Features
Drive Active (System ON)
Output
The output can be mapped to most of the parameters.
The most common is Drive Enable. This relay output will
be closed when ACS module is running. It is used as the
Start or Run input to the VFD. It is not the Secure Dis-
able input. See F
IG
. 4-F
IG
. 6 on pages 8-10 for further
information.
Back Pressure Regulator (BPR)
Production/Sleep Modes
NOTE: See F
IG
. 4-F
IG
. 6 on pages 8-10 and manual
311606 for wiring and installation details.
Flow Rate Monitoring
Operational Envelope Limit
Explosion-proof electric motors have constant torque
and variable torque limits. E-Flo system is a constant
torque application, and therefore the motor’s constant
torque limits must not be violated. The system is avail-
able from Graco with two motors: the UL/CSA explo-
sion-proof motor and the ATEX explosion-proof motor.
Pressure Limits
If a pressure transducer is present, set the maximum
pressure limits as shown in T
ABLE
6. See Alarm
Enable, page 29.
Table 5: E-Flo Pump Displacement Volumes
Lower Size
Volume per
Cycle (cc)
Volume per
Cycle (Gal)
2000cc 4278 1.13
1500cc 3070 0.81
1000cc 2263 0.60
750 cc 1537 0.41
Table 6: System Pressure Limits
E-Flo
Model
Lower
Size
(cc)
Graco Motor
Non-Graco
Motor
psi bar psi bar
E-Flo 4000 2000 250 17 250 17
E-Flo 3000 1500 330 23 330 23
E-Flo 2000 1000 460 32 460 32
E-Flo 1500 750 425 29 500 35