Calibrate the Transducer
NOTE: Only a 4-20 mA output transducer can be used
with the ACS.
NOTE: Calibration values for a Graco transducer are
listed on the label attached to the pump gearbox circuit
board cover. See F
IG
. 23. For a non-Graco transducer,
refer to the manufacturer’s label or data sheet.
Enter the transducer calibration values where shown in
F
IG
. 24, using the button to raise or lower the set-
point, as desired.
After the values are entered, the ACS will perform the
calibration.
Set the Clock
On the Configuration screen, click on
to access the clock screen
(see F
IG
. 25). There are two methods to set the clock:
• To input the values yourself, use the buttons.
Click on to enter.
• To synchronize the ACS clock with your PC, click on
. All values will be
loaded from the PC and the window will close.
F
IG
. 23. Calibration Label Location
F
IG
. 24. Calibration Values
ti17606a
F
IG
. 25. Set the Clock