User's Manual

Operation
22 3A0006D
Run Screen
See F
IG
. 14. Use the Run screen to start or stop the
pump, reset faults, access the Configuration or Alarm
screen, view setpoints, and monitor the pump’s opera-
tion by viewing performance data.
The Run screen displayed depends on which pump was
selected on the ACS System Status Screen, page 21.
Each Run screen applies only to the selected pump.
Information Bar
The Run screen information bar displays the unique
pump name, the ACS IP address, the date, and the
time.
The Pump Name is not editable on the Run screen, but
may be input on the Configuration screen. See page 24.
Pump Performance Data
Pump Speed
The pump speed is displayed in cycles per minute
(CPM).
Flow
The flow is expressed in gpm or lpm, as selected on the
Configuration screen (see page 25).
Motor Command Hz
The speed command, in Motor VFD frequency (4-20mA
scaled 0-80 Hz). This is not the frequency output by the
VFD.
Fluid Pressure
The fluid pressure is displayed in psi or bar, as selected
on the Configuration screen (see page 25).
Pump Setpoints
Run Setpoint
The Run Setpoint is displayed, as set on the Configura-
tion screen (see page 27).
Sleep Setpoint
The Sleep Setpoint is displayed, as set on the Configu-
ration screen (see page 27).
Pressure Setpoint
The Pressure Setpoint is displayed, as set on the Con-
figuration screen (see page 26).
Fault Status
The screen displays if there is a fault:
•None
High Pressure
Low Pressure
Xducer (Transducer) Fail
Pressure Sensor
Auto Xducer Fail
MIN FLOW Warning
Position Error
Auto Cam Off-Position
Auto Cam Activated
No TDC Signal
•Max Flow
Auto Cam Off-TDC
Start Event
•Stop Event
NOTE: See page 41 for alarm descriptions and trouble-
shooting.
Click on the Reset key to clear.
NOTE: The pump starts after a Reset.
Run Button
Click on the Run key to start the pump.
Stop Button
Click on the Stop key to stop the pump.
NOTE: The Run/Stop buttons function as enable/dis-
able, active management is not necessary. This can be
left in Run and the pump/motor controlled from a physi-
cal start/stop switch connected to VFD.
Motor Status
The screen displays the status of the pump motor:
Stopped - ACS module receiving position pulses
Motor Running - ACS module not receiving position
pulses.