User's Manual
ACS Control Mode
16 3A0006D
ACS Control Mode
The ACS module provides an analog drive signal to the
VFD.
• Run command refers to an input command to the
VFD, requesting the motor to run in designated
direction.
• Stop command refers to an input command
removed, requesting the motor to stop running.
The VFD drives the pump if the following conditions are
met:
• SECURE/DISABLE switch is ON
• START/STOP switch is ON
• There are no VFD or ACS faults
NOTE: The local control box cannot make flow rate
changes. Use automation (PC, VB software, or process
controller) to change the flow rate.
A control with interface must be used to select a drive
speed.
NOTE: See the schematic diagrams on pages 8-10 for
wiring details to complete the installation.
F
IG
. 7. Local Control Box
120991 ATEX Control Box
120373 UL/CSA Control Box
TI10719A
SECURE
DISABLE
(wired to VFD)
START/STOP
(wired to VFD)
FAULT RESET
(wired to ACS)
Not Used
Not Used
SECURE
DISABLE
(wired to
VFD)
START/STOP
(wired to VFD)
FAULT
RESET
(wired to
ACS)