User's Manual

ACS Control Mode
16 3A0006D
ACS Control Mode
The ACS module provides an analog drive signal to the
VFD.
Run command refers to an input command to the
VFD, requesting the motor to run in designated
direction.
Stop command refers to an input command
removed, requesting the motor to stop running.
The VFD drives the pump if the following conditions are
met:
SECURE/DISABLE switch is ON
START/STOP switch is ON
There are no VFD or ACS faults
NOTE: The local control box cannot make flow rate
changes. Use automation (PC, VB software, or process
controller) to change the flow rate.
A control with interface must be used to select a drive
speed.
NOTE: See the schematic diagrams on pages 8-10 for
wiring details to complete the installation.