Maximum working air pressure ............................................... 100 psig (7 bar)
Air supply ........................................................75 to 100 psig (5 to 7 bar)
Air filtration
Air logic (Graco supplied) ..................................................... 5 micron
Air purge (user supplied) ............................................ 30 micron clean/dry
Air for atomizing (user supplied) .............................. minimum of 30 micron clean/dry
Mix ratio range
Sequential dosing........................................................ 0.1:1 to 50:1
Dynamic dosing ......................................................... 0.1:1 to 30:1
Ratio accuracy........................................... up to ±1% minimum (user selectable)
Fluids handled .............................. one or two component: solvent and waterborne paints;
polyurethanes; epoxies; acid catalyzed varnishes; moisture sensitive isocyanates
Fluid filtration ............................................................. 100 mesh min
Flow meters:
METER TYPE MAX PRESSURE FLOW RANGE VISCOSITY
G250 Spur Gear 250 psi (17.2 bar) 75-3800 cc/min 20-3000 cps
G250HR Spur Gear 250 psi (17.2 bar) 38-1900 cc/min 20-3000 cps
G3000 Spur Gear 4000 psi (275 bar) 75-3800 cc/min 20-3000 cps
G3000HR Spur Gear 4000 psi (275 bar) 38-1900 cc/min 20-3000 cps
HG6000 Helical Gear 6000 psi (413 bar) 50-7500 cc/min 30-100,000 cps
1/4” Coriolis Single Tube 2300 psi (158 bar) 20-3800 cc/min* 0.1-3000 cps
3/8” Coriolis Single Tube 2300 psi (158 bar) 50-3800 cc/min* 0.1-3000 cps
S3000 (Solvent Meter) Spur Gear 3000 psi (206 bar) 50-2000 cc/min 0.5-1000 cps**
*Ratio and K-factor dependent
**No filled materials
Component working pressure
Wall fluid panel (no meters) ........................................... 4000 psig (275 bar)
RoboMix fluid panel (G250 meters)...................................... 250 psig (17.2 bar)
Flow control regulator ................................................. 200 psig (13 bar)
Low pressure color change valves ...................................... 300 psig (20.6 bar)
High pressure color change valves .................................... 3000 psig (206.7 bar)
External power supply requirements ................... 85-250 Vac, 50/60 Hz. 2 amps maximum draw,
15 amp maximum circuit breaker required,
8 to 14 AWG power supply wire gauge
Operating temperature range........................................... 41 to 122°F (5 to 50°C)
Noise level
Sound pressure level .................................................... below 70 dBA
Sound power level ...................................................... below 85 dBA
Wetted parts ...................................... 303 SST, 17-4 SST, PTFE, perfluoroelastomer,
tungsten carbide with nickle binder
Weight
EasyKey display ...................................................... 21.75 lb (9.8 kg)
Remote operator station................................................ 0.95 lb (0.43 kg)
Wall fluid panel (no meters) ............................................... 50 lb (22.7 kg)
RoboMix fluid panel (G250 meters included)................................. 31.6 lb (14.3 kg)
Flow control regulator ..................................................... 4 lb (1.8 kg)
Approved for hazardous locations ......................... US and Canada - class 1 Div 1 Group D T3
Europe - Zone 0 Ex ia IIA T3/ATEX II2G T3
Environmental condition rating...................indoor use, pollution degree (2), installation category II
Technical Specifications
ProMix 2KS