User's Manual

Installation
4 333391B
Installation
Dyna-Star Pump Current Control
Adjustment
NOTE: The Dyna-Star Pump is designed to draw 40
Current Amps. The AC to DC conversion kit is only
designed for 20 Current Amps. The current control must
be adjusted on the Dyna-Star Motor Control Board for
20 Current Amps. The Dyna-Star pump will not run effi-
ciently if this adjustment is not made.
1. Disconnect power to Dyna-Star pump.
2. On Dyna-Star pump, remove screws (116) from
motor control box cover (120) and remove cover
and gasket (119) (F
IG. 1).
3. Turn current control potentiometer knob
counter-clockwise to decrease the Amp setting
value to the setting shown in F
IG. 2.
4. Replace motor control board gasket (119) and cover
(120) with screws (116) (F
IG. 3) being careful not to
pinch any wires. Tighten bolts securely. Torque to
17 - 19 ft lbs (23 - 25 N.m).
FIG. 1
116
120
119
FIG. 2
FIG. 3
116
120
119