Grounding Procedure (For Flammable Materials Only)
8 333388B Operation
Grounding Procedure
(For Flammable Materials Only)
1. Position striper so that the tires are not on pave-
ment.
2. Striper is shipped with a grounding clamp. Grounding
clamp must attach to grounded object (e.g. metal
sign post).
Pressure Relief Procedure
1. Perform Grounding Procedure if using flammable
materials.
2. Set both (2) pump valves to
OFF
. Turn engine
OFF
.
3. Turn pressure control to lowest setting. Trigger all
guns to relieve pressure.
4. Engage all gun trigger locks. Turn both (2) prime
valves down.
This equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape
wire for the electric current.
ti23146a
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
ti23144a
ti3441a
PAINT
ti3305a
ti3324a
ti6473a