Smart Control Operation
333388B Operation 25
5. Extend steel tape to distance greater than 26 ft. (8m).
6. Press
to
select Setup/Information.
7. Press for Calibration. Set TRAVEL DIST to 25 ft
(7.6m) or longer. Longer distances ensure better
accuracy, depending on conditions.
\
8. Align calibration bar rear edge with 1 foot (30.5cm)
on steel tape.
9. Push gun trigger control to start calibration.
10. Move striper forward. Keep calibration bar over steel
tape.
11. Stop when calibration bar rear edge aligns with 26-ft.
(8m) on steel tape (25-ft./ 7.6m distance).
12. Push gun trigger control to complete calibration.
Calibration is not complete when the exclamation
symbol is displayed.
Calibration is finished when the check mark symbol
is displayed.
13. Calibration is now complete.
Go to Measure Mode and verify accuracy by measuring
the tape (see Measure Mode, page 27).