User's Manual

Technical Data
126 333347F
Three Phase
NOTE: Times are approximate and may vary with ambient conditions, voltage configuration, and machine
configuration.
System
Channels
(#)
Hose
Length
ft (m)
Start Time in Minutes
20 Amp
Breaker
240V
30 Amp
Breaker
240V
40 Amp
Breaker
240V
50 Amp
Breaker
240V
20 Amp
Breaker
208V
30 Amp
Breaker
208V
40 Amp
Breaker
208V
50 Amp
Breaker
208V
1
4 (1.2)
11 9.9 9.9 9.9 13 13 13 13
1
12 (3.6)
13 9.9 9.9 9.9 14 13 13 13
1
25 (7.6)
15 9.9 9.9 9.9 16 13 13 13
2
4 (1.2)
13 9.9 9.9 9.9 14 13 13 13
2
12 (3.6)
16 11 9.9 9.9 17 13 13 13
2
25 (7.6)
20 14 10 9.9 22 14 13 13
3
4 (1.2)
14 9.9 9.9 9.9 16 13 13 13
3
12 (3.6)
18 12 9.9 9.9 20 13 13 13
3
25 (7.6)
25 17 13 9.9 26 18 13 13
4
4 (1.2)
15 10 9.9 9.9 17 13 13 13
4
12 (3.6)
21 14 11 9.9 23 15 13 13
4
25 (7.6)
30 20 15 12 34 22 17 13
5
4 (1.2)
17 11 9.9 9.9 19 13 13 13
5
12 (3.6)
23 16 12 9.9 27 18 14 13
5
25 (7.6)
34 23 17 14 40 27 20 16
6
4 (1.2)
18 12 9.9 9.9 21 14 13 13
6
12 (3.6)
26 17 13 11 30 20 15 13
625 (7.6)3926191646312319
14 (1.2)1715151520202020
1
12 (3.6)
19 15 15 15 20 20 20 20
1
25 (7.6)
21 15 15 15 22 20 20 20
2
4 (1.2)
19 15 15 15 20 20 20 20
2
12 (3.6)
23 15 15 15 24 20 20 20
2
25 (7.6)
26 18 15 15 28 20 20 20
3
4 (1.2)
20 15 15 15 22 20 20 20
3
12 (3.6)
26 17 15 15 28 20 20 20
3
25 (7.6)
31 21 16 15 34 23 20 20
4
4 (1.2)
22 15 15 15 24 20 20 20
4
12 (3.6)
28 19 15 15 32 22 20 20
4
25 (7.6)
35 24 18 15 40 27 20 20
5
4 (1.2)
22 16 15 15 26 20 20 20
5
12 (3.6)
31 21 16 15 36 24 20 20
5
25 (7.6)
40 27 20 16 47 31 24 20
6
4 (1.2)
24 16 15 15 28 20 20 20
6
12 (3.6)
34 23 17 15 40 27 20 20
6
25 (7.6)
45 30 23 18 53 35 27 21
HM25HM50