User's Manual
Table Of Contents

Technical Data
333347F 125
Startup Time
Single Phase
NOTE: Times are approximate and may vary with ambient conditions, voltage configuration, and machine
configuration.
System
Channels
(#)
Hose
Length
ft (m)
Start Time in Minutes
20 Amp
Breaker
240V
30 Amp
Breaker
240V
40 Amp
Breaker
240V
50 Amp
Breaker
240V
20 Amp
Breaker
208V
30 Amp
Breaker
208V
40 Amp
Breaker
208V
50 Amp
Breaker
208V
1 4 (1.2) 11 9.9 9.9 9.9 13 13 13 13
1 12 (3.6) 13 9.9 9.9 9.9 14 13 13 13
1 25 (7.6) 15 9.9 9.9 9.9 17 13 13 13
2 4 (1.2) 13 9.9 9.9 9.9 15 13 13 13
2 12 (3.6) 16 9.9 9.9 9.9 18 13 13 13
225 (7.6)20139.99.923131313
3 4 (1.2) 15 9.9 9.9 9.9 17 13 13 13
312 (3.6)19129.99.922131313
3 25 (7.6) 26 16 12 9.9 29 19 13 13
4 4 (1.2) 16 9.9 9.9 9.9 18 13 13 13
412 (3.6)22149.99.925161313
425 (7.6)3120141235231613
54 (1.2)18119.99.920131313
5 12 (3.6) 25 16 11 9.9 28 18 13 13
525 (7.6)3623171441271915
64 (1.2)20129.99.922131313
612 (3.6)2818131032201313
625 (7.6)4127201647312218
14 (1.2)1715151520202020
1
12 (3.6)
19 15 15 15 21 20 20 20
1
25 (7.6)
21 15 15 15 24 20 20 20
2
4 (1.2)
19 15 15 15 21 20 20 20
2
12 (3.6)
23 15 15 15 26 20 20 20
2
25 (7.6)
27 17 15 15 30 20 20 20
3
4 (1.2)
21 15 15 15 24 20 20 20
3
12 (3.6)
27 17 15 15 30 20 20 20
3
25 (7.6)
32 21 15 15 36 23 20 20
4
4 (1.2)
23 15 15 15 26 20 20 20
4
12 (3.6)
30 19 15 15 34 22 20 20
4
25 (7.6)
37 24 18 15 42 27 20 20
5
4 (1.2)
25 16 15 15 28 20 20 20
5
12 (3.6)
34 22 16 15 38 25 20 20
5
25 (7.6)
42 28 20 16 48 31 23 20
6
4 (1.2)
27 17 15 15 30 20 20 20
6
12 (3.6)
37 24 18 15 42 27 20 20
6
25 (7.6)
47 31 23 18 54 36 26 21
HM25HM50