User's Manual
Troubleshooting
Troubleshooting Troubleshooting
Troubleshooting
Problem Problem
Problem
Cause Cause
Cause
Solution Solution
Solution
Powerisnoton.Turnpowersupplyon. Displayiscompletelydark.
Looseordisconnectedpower
cable.
Tightenorconnectcable.
Incorrectberopticcable
connections.
Checkconnections.See
FiberOpticConnections,page7.
Badberopticcable.Checkcablefordamage.Replace
orrepairberopticcable.See
FiberOpticCableRepair,page25
Gunisonbutnonumbersare
showing.
Gunboarderror.Turnoffturbineair,thenturnback
ontocyclepowertogunboard.
Clockstopsfunctioning
Deadbattery.
Replacebattery.See
ReplaceBattery,page24
Displayhaspowerbutdoesnot
function.
Hardwarefailure.
Replacedisplaymodule.
Diagnostic Diagnostic
Diagnostic
Information Information
Information
TheLEDsonthebottomofthecontrolmodulegiveimportantinformationaboutsystemfunction.
LED LED
LED
Signals Signals
Signals
Signal Signal
Signal
Description Description
Description
GreenOnControlmoduleispoweredup.
YellowInternalcommunicationinprogress.
Redsolid
Controlmodulefailure.SeeTroubleshooting,page23.
RedashingSoftwareisupdating.
RedashingslowlyTokenerror;removetokenanduploadsoftwaretokenagain.
332989A 23