User's Manual

Technical Data
Technical Data
Positive Displacement
Proportioner
U.S.
Metric
Maximum fluid working
pressure:
MC0500 Systems with
Low-Pressure Pumps
300 psi 2.1 MPa, 21 ba
r
MC0500 Systems with
High-Pressure Pumps
1500 psi 10.5 MPa, 10
5bar
MC1000 Air Spray Systems
300 psi 2.1 MPa, 21
bar
MC2000 Air-Assisted Spray
Systems
1500 psi 10.5 MPa,
105 bar
Maximum w
orking air pressure:
100 psi 0.7 MPa, 7
.0 bar
Air supply: 85–100 psi
0.6–0.7
MPa, 6.0–7.0 bar)
Air filt
er inlet size:
3/8 npt
(f)
Air filt
ration for air logic
(user-
supplied):
5micro
n (minimum) filtration required; clean and dry air
Air fil
tration for atomizing air
(user
-supplied):
30 mic
ron (minimum) filtration required; clean and dry air
Mixing ratio range:
0.1:
1 50:1, ±1%
Fluids handled:
one o
r two component:
solvent and waterborne paints
polyurethanes
•epoxies
acid catalyzed varnishes
moisture sensitive isocyanates
Viscosity range of fluid:
20
–5000 centipoise
Fluid filtration (user-supplied):
1
00 mesh minimum
Maximum fluid flow: 800 cc/minute (depending on material viscosity)
Fluid outlet size:
1/4 npt(m)
External power supply
requirements:
90 - 250 Vac, 50/60 Hz, 7 amps maximum draw
15 amp maximum circuit breaker required
8 to 14 AWG power supply wire gauge
Operating temperature range: 36 to 122°F 2 to 50°C
Storage temperature range: –4 to 158°F –20 to 70°C
Weight (approximate):
195lb 88kg
Sound data: Less than 75 dB(A)
Wetted parts:
17–4PH, 303, 304 SST, Tungsten carbide (with nickel binder),
perfluoroelastomer; PTFE, PPS, UHMWPE
332562B 75