User's Manual

Color Change
Color Change
Color Change Module Kits are available as an
accessory. See manual 332455 for complete
information.
Single Color Systems
1. Follow the p
rocedure under
Flush the Sy
stem, page 28.
2. Load the new
color. See
Prime and F
ill the System, page 25.
3. Press the M
ix key
to start spraying.
Multiple Color Systems
1. Press Standby .
2. Set the current mix manifold to FLUSH.
3. Select the new recipe at the Booth Control or
on the Spray Screen, page 34. This will change
colors in the pump and initiate a gun purge. The
Standby and Purge indicators should be blinking.
NOTE: The booth control only displays enabled
recipes. If an invalid recipe is entered, the
display will show 4 dashes (— ). See
Recipe Screen, page 45 to enable a recipe.
NOTE: If Mix at Wall is enabled on
System Screen 3, page 42, the system
will purge Material B first, then Material A
out of the gun. Each material will purge for
the amount of time designated by the Flush
Sequence selected for that material on the
Recipe Screen, page 45.
4. Hold a metal part of the gun firmly to a grounded
metal pail. Trigger the gun. Make sure there is
enough flow to open the solvent flow switch.
5. Release the trigger when the solvent flow stops
and the Purge indicator stops blinking.
NOTE: If you are using quick-disconnects at the
mix manifold, disconnect the gun from the purged
mix manifold and connect it to the new color line.
6. Wait for the color change to complete (the
Standby indicator is on solid).
7. Set the mix manifold to SPRAY.
8. Press the Mix key
on the booth
control. The Mix indicator will be blinking.
9. Trigger the gun to complete the Mix Fill.
NOTE: There is a 30 second delay without flow
before the system will fault.
10. Wait for atomizing air and for the Mix indicator to
be on solid, then resume spraying.
60 332562B