User's Manual

Setup M ode Scree
ns
Pump Screen 2
Pump screen 2 sets the pressure transducer settings
for the pump.
Figure 45 Pump Screen 2, Default Settings Enabled
Figu
re 46 Pump Screen 2, Default Settings Disabled
Default Settings Selected
When the “Use Default Settings” box is selected,
default settings are used for the calibration values,
and the fields are grayed out.
Default Settings Not Selected
When the “Use Default Settings” box is not selected,
the following calibration values must be entered.
Invalid values will be over-ridden and the system will
automatically select the default settings.
•InletOffs
et Factor: This field is only used if Inlet
Pressure i
n Pump Screen 1, page 48 is set to
Monitor; i
t is grayed out if set to Disabled. The
valid ran
ge is -01.20 to +01.20 mV/V.
•InletSen
sitivity Factor: This field is only used if
Inlet Pre
ssure in Pump Screen 1, page 48 is set
to Monito
r; it is grayed out if set to Disabled. The
valid ra
nge is 18.80 to 21.20 mV/V.
•OutletO
ffset Factor: The valid range is -01.20 to
+01.20 m
V/V.
•OutletS
ensitivity Factor: The valid range is 18.80
to 21.2
0mV/V.
332562B 49