User's Manual
Setup Mode Scree
ns
System Screen
2
System screen 2 sets the following system operating
parameters.
Figure 31 System Screen 2, in Standby Mode
Figu
re 32 System Screen 2, in Mix Mode
Mix Pressure Tolerance
The pressure of one component must be within
a percentage (±) of the pressure of the other
component during spray or mix. Set the desired Mix
Pressure Tolerance in this field. The default is 75%.
Mix Idle Timeout
The air flow switch (AFS) detects air flow to the gun
and signals that the gun is triggered. If you are not
using an air flow switch, the system does not know if
the gun is spraying. If a pump failed you could spray
pure resin or catalyst without knowing. This should
be caught by the Mix No Flow Timeout; the default
is 5 seconds. The Mix Idle Timeout will trigger Idle
mode, which will run a pump stall test to check for
leaks, then put the pumps in Standby (holding their
current position) after the designated period of time.
Enter the desired Mix Idle Timeout in this field.
See Air F
low Switch (AFS) Function, page 61.
Mix No Fl
ow Timeout
The air
flow switch (AFS) detects air flow to the gun
and sig
nals that the gun is triggered. If the air flow
switch
indicates that the gun is triggered, but there is
no fluid
flow through a pump, you could spray pure
resin o
r catalyst without knowing. The Mix No Flow
Timeou
t will cause the system to shutdown after the
desig
nated period of time. The default is 5 seconds.
Enter
the desired shutdown time in this field.
See Air Flow Switch (AFS) Function, page 61.
40 332562B