User's Manual

Operation
8 332540E
Reservoir Installation
1. Mount Reservoir on sturdy, flat surface. Note loca-
tion of Fill Port (G) and Lubricant Outlet Connection
(A) for easy access once installed.
2. Connect High Pressure Lubricant Supply Line (D) to
the Lubricant Outlet Connection (A).
3. Ground system (see Grounding). Mount reservoir
to grounded chassis member.
Pump Installation
Pump installation instructions are provided in the
Dyna-Star HP or HF Pump instruction manual 332514
provided with your system.
Vent Valve Kit
The vent valve is used to reduce system pressure and
allow the injector to reset. When energized, grease is
pumped out through the outlet port (marked 0) on the
vent valve. When de-energized, it vents pressure inter-
nally to tank.
Refer to the Dyna-Star HP or HF Vent Valve Kit manual
332515 for installation and operation instructions.
Auto-Fill Shut Off
The Auto-Fill Shut Off is used refilling the grease
tank/reservoir instead of the fill port (G). When the
grease level in the tank is full, the Auto-Fill Shut Off
automatically ends the filling operation. Refer to the
Auto-Fill Shut Off Kit instruction manual 332518 for
complete instructions and additional information.
Operation
Read and follow instructions supplied with each sys-
tem component.
Reference letters used in the following Installation
instructions, refer to Typical Installation Key, page
5.
Start-up
Priming
1. After reservoir/tank is completely filled, remove high
pressure lubricant supply line (D) from the outlet.
2. Connect power to pump.
3. Start pump and run pump until all air has been
expelled and fluid flow is continuous.
4. Reconnect the high pressure lubricant supply line
(D) to outlet.
HEAVY EQUIPMENT HAZARD
Equipment is heavy. To avoid injury:
Be sure unit is securely mounted before operation.
Do not lift pressurized equipment.
Lifting or moving heavy equipment incorrectly can
cause serious injury. To avoid serious injuries,
such as muscle strain or back injuries, when
moving pump always use a lifting aid secured to
the pump lift ring. See Technical Data, in the pump
instruction manual for pump weight.
Do not insert finger into the overflow port while filling
a reservoir equipped with a follow plate. Injury or
amputation could result.