User's Manual

Installation
332515E 3
6. Remove screws (e) and washers (f) holding
Dyna-Star Pump to reservoir cover (b) and remove
pump from cover (F
IG. 4).
7. Remove the screws (g) (holding the reservoir cover
(b) to the reservoir (h) (F
IG. 5).
8. (If previously installed) remove follower plate from
inside reservoir.
9. Determine the correct cable length to use for your
pump reservoir.
Short cable is used with 60# reservoirs.
Long cable is used with 90# reservoirs.
Remove and discard the cable you are not using and the
Notice label attached to the cables.
10. For easy wiring, make sure the DIN connector is
facing out (F
IG. 6). Feed the low level cable (j)
through accessory hole (aa) in the reservoir cover
(b). Wrench tighten low level in place.
FIG. 3
FIG. 4
d
c
e
f
b
FIG. 5
NOTICE
Failure to use the correct cable length could result in
inaccurate level indication and low level shutdown.
FIG. 6
g
b
h
j
aa
b