User's Manual

Installation
5. The PD2K uid panel cover was previously
removed in Air Connections, page 11. Thread
the 2–wire cable (22) through the grommet (42)
on the bottom of the fluid panel and up into
the electrical box through an existing grommet
and the wireway. Connect the cable (22) to the
appropriate terminals on the top of the 48 Vdc
power supply (P3 for pump 3, P4 for pump 4);
redwireto+terminal,blackwireto-terminal.
Figure 8 48 Vdc Power Supply Connection
Points
6. Install the dual grommet (11, shipped loose) on
thefreeendoftheD-SUBcable(8).
7. Fasten the grommet (11) to the side of the
electrical control box, using two screws (31).
8. Reinstall the covers on the PD2K electrical
control box and on the fluid panel.
14
332456B