User's Manual

Appendix B - ADM Setup Screens Overview
313997W 81
Advanced Screen 3
This screen allows the user to control the availability of
some key system features.
Disable Dispensing From Display: Check this box
to disable dispensing from the ADM. A footswitch,
dispense valve trigger, or other external signal will
be the only way to initiate a dispense.
Disable Modifying Temp Setpoint: Check this box
to disable modifying temperature setpoints from the
Run screens. This is only applicable if temperature
control items are installed and enabled.
Disable Operator Mode Adjustments: When this
box is checked, the user will not be able to adjust
the dispense settings in Operator Mode.
Low Heater Temp Disables Dispense: When this
box is checked, the system will reject dispense
requests when any enabled heat zones are below
their setpoint.
High Chiller Temp Disables Dispense: When this
box is checked, the system will disable dispensing
when any enabled chiller zones are above their set-
point.
Operator Mode Cavitation Alarm: Check this box
to enable cavitation alarms in Operator Mode. Clear
this box to disable cavitation alarms in Operator
Mode.
Complete Dispense with Setpoint Error: When
this box is checked, the shot will continue dispens-
ing even if the system never reaches the desired
setpoint.
Enable Shot Aborted Notification: When this box
is checked, a pop-up notification will be displayed
when a shot is aborted.
Enable Ratio Check Weight Mode Entry: This
option is for machines without flow meters. When
this box is checked, after any ratio check shot a
popup window will appear asking the user to enter
the dispensed weights. Press the Cancel button to
abort the entry or press the Enter button to record
the new values.
Advanced Screen 4
Limit Rate on Stall to Pressure: Check this box to
allow the HFR to increase to stalling pressure at a
slower, more controlled rate.
Enable Diagnostic Screen: Check this box to
enable the optional ADM screens, enabling USB log
downloading, and erasing USB logs. For more infor-
mation about USB operation, see Appendix F -
USB Operation on page 102. For more information
about the optional screens, see Diagnostic screen
on page 87.
Low Material Disables Dispense: When this box is
checked, the current dispense will terminate and
prevent additional dispenses when the supply sys-
tem indicates a low level.
Advanced Screen 5
This screen displays software information.
Numbers shown are for reference only and may
be different on your system.