User's Manual

Appendix B - ADM Setup Screens Overview
313997W 75
System Screen 3
This screen allows the user to edit the labels for the A
(Red) and B (Blue) sides of the machine. The labels set
for the A (Red) and B (Blue) sides of the machine are
displayed throughout the screens. Labels are limited to
five characters.
To edit a label:
1. Press .
2. To edit the A (Red) label, press .
To edit the B (Blue) label, press the down arrow
then press . The keyboard will appear on the
screen. See Keyboard Screen on page 75.
3. Use arrow keys to select the desired letter and
press to accept the letter. To erase all text, press
the Eraser softkey. To go back one letter, press the
Back Arrow softkey.
4. When finished entering the new label, press
the button twice.
The pressure imbalance setting may be set from this
screen. Pressure imbalance is the allowable difference
in pressure between the two materials before an alarm
is triggered. The input range is 250-2000 psi (2-14 MPa,
17-138 bar).
The flowmeter types are defined on this screen. The
ratio deviation value is the allowable percentage before
the machine displays a pop-up notification. The ratio
alarm value is the allowable percentage difference
before the machine will stop a dispense.
This screen allows the user to enter material specific
gravities.
Keyboard Screen
This screen is used to edit the A (Red) and B (Blue)
labels on the ADM. Use arrow keys to select the desired
letter and press to accept the letter.
1. Use arrow keys to select the desired letter and
press to accept the letter. To erase all text, press
. To delete one letter, press . To move the
cursor one letter to the left, press . To move the
cursor one letter to the right, press . To toggle
the letters from upper/lower case, press .
2. When finished entering the new label, press .
Flow Meter Calibration
Refer to the HFR Flow Meter Kits manual for instructions
on how to calibrate the flow meters.
Pressure
Imbalance
Setting