System Screen 1
NOTE: Not all of the following modes may be available
depending on the dispense valve selected.
This screen allows the user to set important system set-
tings specific to what dispense applicator has been
selected. Control Mode can be set to Pressure or Flow.
With Control Mode set to Pressure, the machine will
adjust dispense flow rate in order to maintain the
requested pressure. With Control Mode set to Flow, the
machine will dispense at a continuous flow rate regard-
less of pressure fluctuations unless pressure alarm con-
ditions occur.
Dispense Mode can be set to Time, Volume, or Weight.
Dispense Mode controls how displayed amounts are
measured. If Dispense Mode is set to Weight, then the
machine dispenses until the desired weight of material
is dispensed. See Calibrate HFR on page 48 for more
information.
Pump sizes and inlet pressures must be entered on this
screen.
If pump sizes and inlet pressures are not entered prop-
erly, system performance will be affected. The inlet pres-
sure must be set to the maximum feed pressure that will
be seen by that side of the machine.
The maximum working pressure for the machine is dis-
played on this screen. The maximum working pressure
is dependent on the installed hoses and dispense valve.
The maximum working pressure is set to the lowest
rated system component. If 2000 psi hoses are installed
and the maximum working pressure displayed is not
2000 psi, see HFR repair/parts manual for instructions
to set the maximum working pressure for hoses. If the
installed dispense valve rating is below the maximum
working pressure shown here, verify the correct dis-
pense valve is selected on System Screen 2.
System Screen 2
This screen allows the user to set the Gel Timer proper-
ties and set which items are installed on the machine.
When enabling the Gel Timer, the user must select one
of the 100 available shot definitions to use as the Gel
Shot. This shot will be dispensed when the Idle Period
expires. The Idle Period will begin after a dispense is
completed. Any dispense operation in the middle of the
timer countdown will reset the Idle Period counter. The
system will generate an audible alarm based upon the
user Alarm setting. The alarm will sound the
user-entered number of seconds before the Idle Period
expires.
The hydraulic level sensor and hydraulic RTD for both
the pump line and mix head must be marked as enabled
when installed in the system. If the sensors are not
marked as enabled, they will be ignored by the machine
controls.
Select the dispense valve installed in the system. This
selection is critical to ensure proper operation of the
machine. When a mix head is selected, button will
become active when the is pressed. When active,
pressing this button will open a screen used to define
the mix head operating parameters. See the Mix Head
Operating Details Screen on page 74.
Selecting the dispense valve will limit the system maxi-
mum working pressure to the maximum working pres-
sure of the dispense valve. See System Screen 1 on
page 73.
Post Dispense Shot Disable is a feature where the user
can disable shot requests for zero to five seconds after
the completion of a dispense. This feature is not applica-
ble for P2/Fusion Dispense Valves. This feature can not
be active if the Pre Dispense Delay feature is active.