Maintenance
313997W 53
Maintenance
Change Break-in Oil
After initial break-in, see Table 5 for recommended fre-
quency of oil changes.
Table 2: Frequency of Oil Changes
Grease Circulation Valves With Fusion
Grease (117773)
Check Hydraulic Fluid Level
Check hydraulic fluid level on dipstick (DS). Fluid level
must be between indent marks (IM) on dipstick. Refill as
required with approved hydraulic fluid; see Technical
Data on page 108. If fluid is dark in color, change fluid
and filter.
Task Schedule
Change break-in oil in a new unit After first 250
hours of opera-
tion or within 3
months, which-
ever comes first
Inspect hydraulic and fluid lines
for leaks
Daily
Inspect fluid inlet strainer
screens, page 56
Daily
Inspect IsoGuard Select fluid
level and condition, refill or
replace as needed, page 57
Daily
Check hydraulic fluid level Weekly
Grease circulation valves with
Fusion grease (117773)
Weekly
Verify operation of air drying sys-
tem to prevent isocyanate crystal-
lization
Weekly
Verify vent holes on bottom of
electrical cabinet are clear and
unobstructed
Weekly
Inspect air filter (part 24H018),
clean or replace as necessary,
Daily
Use compressed air to remove
dust buildup on control boards,
fan, motor (under shield), and
hydraulic oil coolers
Monthly
Clean up all hydraulic leaks; iden-
tify and repair cause of leak
As needed
Clean dispense valve mix cham-
ber ports regularly, see dispense
valve manual
See dispense
valve manual
Clean dispense valve check valve
screens, see dispense valve
manual
See dispense
valve manual
Ambient
Temperature
Recommended
Frequency
0 to 90°F
(-17 to 32°C)
1000 hours or 12 months,
whichever comes first
90°F and above
(32°C and above)
500 hours or 6 months,
whichever comes first
ti9879a1
S
DS
ti7861a1
IM
24C352_313998_1