4. Connect feed lines
a. Install feed pumps (K) in component A (Red)
and B (Blue) supply drums. See F
IG. 1 and FIG.
2, pages 23 and 25.
NOTE: A minimum feed pressure of 50 psi (0.35 MPa,
3.5 bar) is required at both feed inlet pressure gauges
(FP). Maximum feed pressure is 250 psi (1.75 MPa,
17.5 bar). Maintain A (Red) and B (Blue) feed pressures
within 10% of each other.
b. Seal component A (Red) drum and use desic-
cant dryer (M) in vent.
c. Install agitator (L) in component B (Blue) drum,
if necessary.
d. Ensure A (Red) and B (Blue) inlet valves (FV)
are closed.
NOTE:
Supply hoses from feed pumps should be 3/4 in.
(19 mm) ID minimum.
e. Connect and tighten component B (Blue) supply
hose to the 3/4 npt(f) swivel on the component B
(Blue) inlet valve.
f. Connect and tighten component A (Red) supply
hose to the 1/2 npt(f) swivel on the component A
(Red) inlet valve.
5. Connect pressure relief lines
a. Recommended: Connect high pressure hose
(R) to relief fittings (BA, BB) of both PRES-
SURE RELIEF/DISPENSE valves. Route hose
back to component A (Red) and B (Blue) drums.
See F
IG. 1, page 23.
b. Alternately: Secure supplied bleed tubes (N) in
grounded, sealed waste containers (H). See
F
IG. 1, page 23.
6. For Heated HFR models only, install Fluid Tem-
perature Sensor (FTS)
a. Install FTS between main hose and whip hose.
See Heated Hose manual for instructions.
FP
ti10006a1
ti9883a1
FV
Do not install shutoffs downstream of the PRESSURE
RELIEF/DISPENSE valve outlets (BA, BB). The
valves function as overpressure relief valves when set
to DISPENSE . Lines must be open so valves
can automatically relieve pressure when machine is
operating.
If circulating fluid back to the supply drums, use high
pressure hose rated to withstand the maximum work-
ing pressure of this equipment.