User's Manual
Setup
38 313997W
Setup
Perform this setup procedure to secure all necessary
machine connections for machine operation.
1. Locate HFR.
a. Locate HFR on a level surface. See Dimen-
sions on page 110 for space requirements.
b. Anchor the HFR to the floor (suggested
anchors: McMaster Carr anchor, 92403A400).
See Dimensions, page 110, for bolt locations. If
machine mobility is required, purchase Mobile
Pallet Base with Casters Kit, 24P090.
c. Do not expose HFR to rain.
2. Electrical requirements. See Models on page 4
for detailed electrical requirements information.
3. Connect electrical cord.
NOTE: See Power Line Voltage Surges information on
page 39.
NOTE: Power cord is not supplied. See the following
table.
† Residual Current Device (RCD) must be rated at
300 mA if installed.
Electrical Cord Wires by Model
230V, 1 phase: L1, L2, GND
230V, 3 phase: L1, L2, L3, GND
400V, 3 phase: L1, L2, L3, N, GND
Typical Voltage Readings
230V, 1 phase:
L1-L2: 230V
L1 or L2-G: 115V
230V, 3 phase (delta high leg):
L1-L2, L2-L3, L3-L1: 230V
L1-G, L3-G: 115V
L2-G: 208V
400V, 3 phase (Y / wye):
L1-L2, L2-L3, L3-L1: 400V
L1-N, L2-N, L3-N: 230V
L1-G, L2-G, L3-G: 230V
NOTICE
To avoid tipping the machine and personal injury, do
not attach wheels directly to the standard HFR
mounting brackets.
NOTICE
Bolt HFR to original shipping pallet before lifting.
Installing this equipment requires access to parts
which may cause electric shock or other serious injury
if work is not performed properly. Have a qualified
electrician connect power and ground to main power
switch terminals, see step 3 in this setup procedure.
All electrical wiring must be done by a qualified electri-
cian and comply with all local codes and regulations.
NOTICE
Never connect to 480V, 3 phase power. Severe
equipment damage will occur.
Table 1: Power Cord Requirements
Model
Cord Requirements
AWG (mm
2
)
Non-Heated HFR,
230V, 1 phase
6 (13.3), 2 wire + ground
Non-Heated HFR,
230V, 3 phase
8 (8.4), 3 wire + ground
Non-Heated HFR,
400V, 3 phase
6 (13.3), 4 wire + ground †
Heated HFR,
230V, 1 phase
1 (42.4), 2 wire + ground
Heated HFR,
230V, 3 phase
4 (21.2), 3 wire + ground
Heated HFR,
400V, 3 phase
4 (21.2), 4 wire + ground †