User's Manual

Component Identification
26 313997W
Main Power Switch
Located on top of the power distribution box, see
page
25. The main power switch turns power
ON and OFF . The main power switch
does not turn pumps or heat zones on.
Circuit Breakers
Most circuit breakers are located inside the power distri-
bution box. The main block of circuit breakers in the
power distribution box is shown below, with detailed
information in the following table. For more information
about items in the power distribution box, see power dis-
tribution box manual for more information.
Additional circuit breakers for protection of the second-
ary side of the heated hose transformer are located
inside the frame. See the parts list for the installed pri-
mary/hose heat option. See Ref. 5 of the product config-
urator code for your machine to determine which
primary/hose heat option is installed. See Product Con-
figurator on page 5.
Ref.
Size
Component
230V/
1 phase,
400V/
3 phase
230V/
3 phase
CB1 63A 30A Motor Control Module
CB2 40A 40A Primary Heater A
CB3 15A 15A Tank Heat A
CB4 40A 40A Hose Heat A
CB5 5A 5A Miscellaneous
CB6 5A 5A Miscellaneous
CB7 40A 40A Hose Heat B
CB8 15A 15A Tank Heat B
CB9 40A 40A Primary Heater B
CB1
CB5
CB4
CB2CB3
CB9
CB7 CB6
CB8
24C681_313998_1e
CB579
CB718
B (Blue)
Left Side from Rear View
A (Red)
Right Side from Rear View
24C332_313998_3f
24C332_313998_6f