User's Manual

Programming the Lube Sentinel II Monitor
313903C 13
For the following instructions, refer to FIG. 11.
1. Press PRGM button once to enter programming
field.
2. Press SLCT button to move from CONFIGURA-
TION?ZONE1, to CONFIGURATION?ZONE2, to
SERIAL PORT, and to GLOBAL SETTINGS.
3. When the desired field is selected, pressing the
PRGM button scrolls through the options within that
field.
4. Pressing the SLCT button toggles through the
choices available for the selected option.
Saving Program Changes
1. When the display shows CONFIGURA-
TION?ZONE1, CONFIGURATION?ZONE2,
SERIAL PORT, or GLOBAL SETTINGS, press the
RST/CLR button to place the Sentinel II in the moni-
tor mode.
2. A prompt will ask if any changes should be saved.
The default is NO. To save the changes, press the
SLCT button to change to YES.
3. Then press the PRGM button.
NOTE: Pressing any other button when NO is showing
will erase any changes indicated and leave all settings
as they were before entering the programming function.
F
IG. 11
RST/CLR SLCT
PRGM
Press PRGM button to
enter programming field.
Press SLCT button to toggle between four fields.
CONFIGURATION?
CONFIGURATION? SERIAL PORT
GLOBAL SETTINGS
1
2
- ENABLE ZONE
- UNITS OF MEASURE
- PORT TOTAL
- FAULT SETUP
- FLOW ALARM ON
- LOW FLOW SET
- HIGH FLOW SET
- ENABLE TACH
- SET # PULSES/REV
- SET NORMAL RPM
- ENABLE ZONE
- UNITS OF MEASURE
- PORT TOTAL
- FAULT SETUP
- FLOW ALARM ON
- LOW FLOW SET
- HIGH FLOW SET
- ENABLE TACH
- SET # PULSES/REV
- SET NORMAL RPM
- BAUD RATE
- WORD LENGTH
- STOP BITS
- PARITY
- FAULTS TO SKIP
(Nuisance Faults)
- INVERT RELAYS
RST/CLR
SLCT
PRGM
3
Options
Press PRGM button to scroll
through field options.
RST/CLR
SLCT
PRGM
RST/CLR
SLCT
PRGM
Press SLCT button to toggle through choices for
selected options.
4
(Fault Relay Logic)
Fields