User's Manual
System Operation
50 313882C
Start Up
1. Go through the Pre-Operation Checklist in Table 7.
2. Turn the AC Power Switch on the EasyKey and on
the Power Supply Module ON (I = ON, 0 = OFF).
➜ Graco logo, software revision, and “Establishing
Communication” will display, followed by Status
screen. See page 20.
➜ At power up the system defaults to Recipe 61,
which is not a valid recipe number. Initiate a
color change to Recipe 0 or a valid recipe num-
ber (1-60).
➜ In bottom left corner, the system status displays,
which can be Standby, Mix, Purge, or an alarm
notification.
3. Make sure that the Booth Control is working. The
active recipe number should display and the
Standby LED
should be lit.
4. If this is the first time starting up the system, purge it
as instructed in Purging Fluid Supply System,
page 59. The equipment was tested with lightweight
oil, which should be flushed out to avoid contaminat-
ing your material.
5. Make sure that the Booth Control is in Standby
mode.
Table 7: Pre-Operation Checklist
✓ Checklist
System grounded
Verify all grounding connections were made. See
the ProMix 3KS Installation manual.
All connections tight and correct
Verify all electrical, fluid, air, and system connec-
tions are tight and installed according to the
Installation manual.
Fluid supply containers filled
Check component A, B, and C and solvent supply
containers.
Mix manifold valves set
Check that mix manifold valves are set correctly.
Start with the settings recommended in Mix Mani-
fold Valve Settings, page 48, then adjust as
needed.
Fluid supply valves open and pressure set
Component A, B, and C fluid supply pressures
should be equal unless one component is more
viscous and requires a higher pressure setting.
Solenoid pressure set
75-100 psi inlet air supply (0.5-0.7 MPa, 5.2-7 bar)