User's Manual

Location
12 313881B
F
IG
. 3.
Intrinsically Safe Installation
NON-HAZARDOUS LOCATION ONLY
HAZARDOUS (CLASSIFIED) LOCATION
CLASS I, DIV I, GROUP D, T3 (US AND CANADA)
CLASS I, ZONE I, GROUP IIA, T3 (ATEX ONLY)
TAUB = -20°C TO 50°C
ProMix 2KS
EasyKey Interface
(with or without
display)
Safety
Barrier
ProMix 2KS Wall Panel
Flow
Meter
A
Flow
Meter
B
Booth Control
Module
FM08ATEX0073
Color & Catalyst
Change
Module 1
FM08ATEX0073
250 VAC Maximum
Supply Voltage
50’ I/S Power Cable, blue
color coded (3’, 6’, 10’,
15’, 25’, 100’ options)
50’ Fiber Optic
Communication
Cable (100’ option)
10’ I/S Power and
Communication
Cable (40’
extension option)
IS Control Drawing 258682
Cable Assemblies
Module 2
FM08ATEX0073
Flow Control
Regulator
Module
FM08ATEX0073
6’ CAN Color Change
Interface, yellow color coded
(50’ option)
50’ CAN Booth Control
Interface, yellow color coded
(6’ option)
3’ CAN
Network
Cable,
blue
color
coded
NOTE: See Intrinsically Safe Installation Require-
ments on page 11.
WARNING: Substitution of components may impair
intrinsic safety. For installation, maintenance or opera-
tion instructions, see instruction manual.
ADVERTISSEMENT: La substitution de composants
peut compromettre la securite intrinseque.
FM08ATEX0074
SYSTEM ASSEMBLY CERTIFICATE
FM08ATEX0072
ASSOCIATED APPARATUS
FM08ATEX0073 INTRINSIC
SAFE APPARATUS
Safety
Barrier
250 VAC Maximum
Supply Voltage
FM08ATEX0072
ASSOCIATED APPARATUS
ProMix 3KS
Power Supply
Module
50’ I/S Power Cable, red
color coded (100’ option)
Flow
Meter
C
10’ Std CAN Communication Cable,
green color coded (25’ option)
ProMix 3KS
Wall Panel
ProMix 3KS CAN
Isolation Plate
Coriolis Meter Options, DMT 00 ATEX E 074 X
(No exceptions):
Size
Graco
P/N Endress+Hauser P/N
1/8” 15T633* 80A-04-A-SVW-9-A-N-A-B-B-A-S
3/8” 15T634* 801-08-A-999-9-A-N-A-B-B-A-S
* For P/N 15T633 order Coriolis Meter Kit 258150.
For P/N 15T634 order Coriolis Meter Kit 258151.
Power
EasyKey Meter Terminal
Block No.
+24 Vdc
Common
1
2
Signal
Fluid Plate
Board
J3 Terminal Meter Terminal
Block No.
Meter Position A B
Signal 3 6 24
Common 2 5 25
FM08ATEX0073
INTRINSIC SAFE
APPARATUS